| TECHNICAL SPECIFICATIONS |
| OPERATING CONDITIONS |
| Power Supply |
| Mains voltage |
3 x 380V/220V, +5% -10%, 4 wires |
| Power input (fm=1kHz/m=1) |
225 kVA, max |
| Mains frequency |
50 Hz or 60 Hz (as option) |
| Power factor |
cos phi greater than 0,95 |
| Modulator Input |
| Input impedance |
600/2000 Ohms balanced standard |
| Input level (for fm=1 kHz, m=1) (0 dBm 0.775V across 600 Ohms) |
-4 dBm ± 10 dBm |
| Transmitter Output |
| RF output load impedance |
50 ohm unbalanced |
| Permissible VSWR |
s less than 2 at 50 ohm unbalanced |
| Climatic Conditions |
| Temperature in transmitter hall |
+5 to +45 C |
| Max. altitude above sea level |
2000 m |
| Relative humidity |
less than 95 %, non-condensing |
| ELECTRICAL CHARACTERISTICS |
| Frequency Range |
| Frequency range |
3.2 - 26.1 MHz |
| RF Output Power |
| Output power in the range |
100 kW |
| Frequency stability |
108 /day |
| Type of modulation |
High level plate modulation |
| Modulation principle |
SSDM |
| Type of emission |
DSB 9A3, DSB 15A3 As options: DSB with ACC (Adaptive Carrier Control), SSB |
| Modulation Characteristics |
| Signal to Noise Ratio |
| Unweighted |
less than 55 dB Reference level m=100% fm=1 kHz,sinusoidal, mains voltage sinusoidal |
| RF Harmonic and Spurious Radiation |
| RF harmonic and spurious radiation |
less than -63 dB |
| Carrier Shift |
| Carrier shift at m=95% with fm=1 kHz sinusoidal and at a constant mains voltage referred to the unmodulated carrier |
less than 3% |
| Overall Efficiency |
| Carrier with 0 - 100% modulation |
more than 70% |
| Max. Tuning Time |
| Max. tuning time |
30 sec. |
| Audio Characteristics |
| Audio Frequency Response |
±1 dB, 40 Hz to 10 kHz ±0.5 dB, 100 Hz to 5 kHz, at m=0.95 |
| Specifications may change without notice |
|