| TECHNICAL SPECIFICATIONS |
| Frequency range |
5.95 to 26.1 Mc/s |
| Power rating |
250 kW from 3.95 to 17.9 Mc/s, falling to 200 kW at 26.1 Mc/s, at nominal mains voltage |
| Frequency stability |
Better than 5 parts in 106 per month |
| Output impedance |
Balanced 270 to 330 ohm |
| Drive input |
5 W at radiated frequency |
| Frequency response |
±1 dB between 50 and 7500 c/s, referenced 400 c/s, measure at 75% modulation |
| A.F harmonic distortion |
Less than 2.5%; 50 to 7000 c/s, at 50% modulation. Less than 4%, 50 to 7000 c/s, at 95% modulation |
| Noise and residual modulation |
At least 56 dB (unweighted) below level corresponding to 100% modulation by sine wave signal at 1000 c/s |
| Power supply |
All auxiliary circuits 380 to 415 V, 3-phase, 4-wire, 50 c/s a.c. |
| Supply voltage regulation |
+6% to -10% deviation from nominal mains voltage (a.v.r fitted to give ±1% for filaments etc.) |
| Frequency regulation |
±4% deviation from nominal mains frequency |
| Overall power factor |
Better than 0.9 |
| Power consumption |
575 kW at 40% sine mod. 860 kW at 95% trap. mod. |
| Floor space required |
Transmitter 27 ft x 16 ft (8.2 x 4.9 m) H.T enclosure 27 ft x 15 ft 9 in. (8.2 x 4.8 m) |
| Specifications may change without notice |